- CAD/CAM으로 제작한 코누스내관의 변연적합
- MARGINAL ADAPTATION OF THE CONICAL INNER CROWN FABRICATED WITH CAD/CAM
- ㆍ 저자명
- 김인섭,강동완,Kim. In-Sup,Kang. Dong-Wan
- ㆍ 간행물명
- 대한치과보철학회지
- ㆍ 권/호정보
- 2002년|40권 1호|pp.30-41 (12 pages)
- ㆍ 발행정보
- 대한치과보철학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM. The informations on abutment teeth were transferred to a computer with a micro contact digitizer, which had a $50{mu}m$ accuracy on the master die. A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial, distal, buccal, and lingual surfaces) of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1 The mean marginal gap between the conical inner crown and abutment tooth was $83.2{pm}43{mu}m$, 28.9% of the specimen showed marginal gap over $100{mu}m$. 2. The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (P<0.05).