- CT 검사에서 시간분석에 의한 필름시스템과 PACS의 비교 연구
- ㆍ 저자명
- 권대철,홍성만,박범,Kweon. Dae-Cheol,Hong. Sung-Man,Park. Peom
- ㆍ 간행물명
- 산업공학
- ㆍ 권/호정보
- 2002년|15권 4호|pp.439-443 (5 pages)
- ㆍ 발행정보
- 대한산업공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this paper, we study to evaluate the relative time required to perform the CT scanning in the PACS versus a film-based system and helical versus non-helical studies. Time studies were performed in 175 consecutive CT scanning. Images from 85 examinations were electronically transferred to a PACS, and 90 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a radiological technologist to complete a CT test was reduced by 43% with the PACS compared with the film-based system and nonhelical was reduced 10~20% with helical studies. This reduction was due to the elimination of a transfer and printing, such as the printing at window or level settings. The use of PACS can result in the elimination of time tasks for the radiological technologist, resulting in marked reduction in examination time. This reduction can result in decreased cost and increased productivity in PACS operation.