- UAM-V를 이용한 부산지역 고농도 오존사례 수치모의
- ㆍ 저자명
- 김유근,오인보,황미경
- ㆍ 간행물명
- 한국대기환경학회지
- ㆍ 권/호정보
- 2003년|19권 1호|pp.1-11 (11 pages)
- ㆍ 발행정보
- 한국대기환경학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Temporal and horizontal distributions of surface ozone concentrations covering the Busan metropolitan area were simulated by UAM -V (The Variable grid Urban Airshed Model) that was run with meteorological inputs taken from MM5 for ozone episode day (18 July 1999). UAM-V underestimated the daily maximum ozone con-centration about 14 ppb on average at all monitoring sites within Busan area comparing with observed value. but the correlation between observed and simulated values showed quite significant (R = 0.896, p< 0.01 on average). Higher concentrations of ozone occurred near the city center and industrial areas (western side of city) with high levels of anthropogenic source in the morning, and transport of ozone and its precursors by sea breeze developed in the afternoon contributed to elevated ozone levels in downwind rural areas. Particalarly in slightly downwind area of city center, the highest daily maximum ozone concentration ($geq$120 ppb) was simulated by UAM-V at 1400 LST. Consequently, local environments including emission distributions and land -sea breeze circulation influenced ozone distributions in the Busan metropolitan area.