- 연약지반에 대한 더치콘과 피에조콘 관입시험 비교 연구
- Comparative Study of Dutch Cone and Piezocone Penetration Test on Soft Ground
- ㆍ 저자명
- 원정윤,장병욱,우철웅,윤상묵
- ㆍ 간행물명
- 한국농공학회지
- ㆍ 권/호정보
- 2003년|45권 2호|pp.96-106 (11 pages)
- ㆍ 발행정보
- 한국농공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
134 Dutch cone (mechanical cone) and 9 piezocone (electronic cone) penetration tests have been performed in the southwestern part of Korea. In general, Dutch cone results may be different from that of piezocone due to the difference in structure of the cones. 6 Dutch cone and piezocone test data which were obtained at the same point respectively, were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986, 1990). Cone factors of Dutch cone and piezocone test empirically have been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Relationship formula was also suggested. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.