기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
조프란 정(온단세트론 8mg)에 대한 온프란 정의 생물학적동등성
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 조프란 정(온단세트론 8mg)에 대한 온프란 정의 생물학적동등성
저자명
신인철,홍정욱,박윤영,고현철
간행물명
The journal of applied pharmacology : the official journal of the Korean Society of Applied Pharmacology
권/호정보
2003년|11권 1호|pp.58-64 (7 pages)
발행정보
한국응용약물학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Ondansetron is a potent, highly selective 5-hydroxytryptamin $e_3$(5-H $T_3$) receptor-antagonist, for the management of nausea and vomiting induced by cytotoxic chemotherapy and radiography, and the treatment of post-operative nausea and vomiting. The purpose of the present study was to evaluate the bioequivalence of two ondansetron tablets, Zofran (Glaxo Smithcline Korea Ltd.) and Onfran (Korea United Pharmaceutical Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). Eighteen normal male volunteers, 24.39$pm$1.69 year in age and 69.00$pm$6.74kg in body weight, were divided into two groups and a randomized 2${ imes}$2 cross-over study was employed. After one tablet containing 8mg of ondansetron was orally administered, blood was taken at predetermined time intervals and the concentrations of ondansetron in plasma were determined using HPLC with UV detector. Pharmacokinetic parameters such as AVC, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters. The results showed that the differences in AUC, $C_{max}$ and T max between two tablets were 5.83%, 5.75% and -5.71%, respectively when calculated against the Zofran, tablet. The powers (1-$eta$) for AUC, $C_{max}$ and $T_{max}$ were above 90%, above 90% and below 60%, respectively. Minimum detectable differences($Delta$) at alpha=0.1 and 1-$eta$=0.8 were less than 20% (e.g., 12.74% and 11.78% for AUC and $C_{max}$ respectively). But minimum detectable differences($Delta$) at alpha=0.1 and 1-$eta$=0.8 for $T_{max}$ were more than 20% (e.g., 34.22%). The 90% confidence intervals were within $pm$20% (e.g., -2.73∼14.39 and -2.16∼13.67 for AUC and $C_{max}$ respectively). But 90% confidence intervals for $T_{max}$ were not within $pm$20% (e.g., -28.71∼17.28). Another ANOVA test was conducted for logarithmically transformed AUC and $C_{max}$. These results showed that there are no significant difference in AUC and $C_{max}$ between the two formulations: The differences between the formulations in these log transformed parameters were all for less than 20% (e.g., 5.83% and 5.75% for AUC and $C_{max}$ respectively). The 90% confidence intervals for the log transformed data were the acceptance range of log 0.8 to log 1.25 (e.g., log 0.99∼log 1.15 and log 0.98∼log 1.15 for AUC and $C_{max}$ respectively). The major parameters, AUC and $C_{max}$, met the criteria of KFDA for bioequivalence although $T_{max}$ did not meet the criteria of KFDA for bioequivalence, indicating that Onfran tablet is bioequivalent to Zofrm1 tablet.t is bioequivalent to Zofrm1 tablet.m1 tablet.m1 tablet.m1 tablet.