기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
시멘트 유지형 임플란트 보철물의 유지력에 시멘트의 종류와 열순환이 미치는 영향에 관한 연구
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 시멘트 유지형 임플란트 보철물의 유지력에 시멘트의 종류와 열순환이 미치는 영향에 관한 연구
  • EFFECTS OF VARIOUS CEMENTS AND THERMOCYCLING ON RETENTIVE STRENGTHS OF CEMENTED IMPLANT-SUPPORTED PROSTHESES
저자명
조재호,정창모,전영찬,Cho. Jae-Ho,Jeong. Chang-Mo,Jeon. Young-Chan
간행물명
대한치과보철학회지
권/호정보
2003년|41권 4호|pp.466-475 (10 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Statement of problem : In cemented implant-supported porstheses, it is still controversy what kind of cement to use. However, the effect of thermocycling on retentive strength of cemented implant-supported prostheses has not been well investigated. Purpose : This study was tested to evaluate the effects of various cements and thermocycling on retentive strengths of cemented implant-supported prostheses. Material and methods : Prefabricated implant abutments, height 5mm, diameter 6mm, 3-degree taper per side, with light chamfer margins were used. Ten specimens of two-unit fred partial denture were fabricated. The luting agents used for this study were three provisional luting agents which were Temp bond, Temp bond NE, IRM and four permanent luting agents which were Panavia F, Fuji-cem, Hy-bond Zinc cement, Hy-bond Polycarboxylate cement. 24 hours after cementation. the retentive strengths were measured by the universal testing machine with a cross-head speed of 0.5mm/min. Then cementation procedures were repeated and specimens were thermocycled 1000 times at temperature of $5^{circ}C$ and $55^{circ}C$. After thermocycling, the retentive strengths were measured. Results : Before thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem. Hy-bond Zinc cement. Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were significant differences among each groups(p<0.05). After thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem, Hybond Zinc cement, Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were no significant differences among Panavia F, Fuji-cem and Temp bond NE, Temp bond(p>0.05). The retentive strengths before and after thermocycling showed significant differences in Hy-bond Zinc cement. IRM, Temp bond NE and Temp bond(p<0.05). Conclusion : Within the limitation of this study, thermocycling do not affect the retentive strengths of permanent luting agents but the retentive strengths of temporary cements were reduced significantly after thermocyling.