기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS
  • A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS
저자명
Park. Chan-Jin,Kim. Yung-Soo,Kim. Chang-Whe,Cho. Lee-Ra,Yi. Yang-Jin
간행물명
대한치과보철학회지
권/호정보
2003년|41권 3호|pp.271-287 (17 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{pm}3.74,;75.76{pm}5.04,;75.73{pm}4.41$ and those of HA-coated surface implant were $75.05{pm}6.23,;77.58{pm}5.23,;78.32{pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.