- 단순접번 교합기의 모형부착 방법에 관한 연구
- ㆍ 저자명
- 조홍규,Cho. Hong-Kyu
- ㆍ 간행물명
- 대한치과기공학회지
- ㆍ 권/호정보
- 2003년|25권 1호|pp.95-102 (8 pages)
- ㆍ 발행정보
- 대한치과기공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The purpose of this study was to show occlusion on the simple hinge articulator optionally mounted. Modelling of upper-lower jaw and simple hinge articulator were developed. This modelling of upper-lower jaw inserting wax bite was mounted imaginary on the modelling of simple hinge articulator by use of the computer simulation. From changes of THA(transverse horizontal axis)-incisor distance, Balkwill angle and THA deviation, eight types were mounted respectively. After removal of wax bite, upper-lower jaw position changing were compared with centric jaw relation. The results were as follows: 1. The change of THA-incisor distance had influence on mostly a vertical shift of upper jaw. 2. The change of Balkwill angle had influence on mostly a horizontal shift of upper jaw. 3. Inferior type in the THA deviations was the least shift of upper jaw. The above results suggest that the simple hinge articulator optionally mounted effect a shift of upper jaw.