- 시차 굴절률 측정에 의한 실시간 글루코오스 모니터링
- ㆍ 저자명
- 정진갑,이명희,최은경
- ㆍ 간행물명
- 韓國染色加工學會誌
- ㆍ 권/호정보
- 2004년|16권 2호|pp.47-51 (5 pages)
- ㆍ 발행정보
- 한국염색가공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
A differential refractive index detector was used for monitoring glucose contents in textile processing solutions. The sensitivity of the device was high enough to measure 0.05% aqueous glucose solution that could not be measured by normal refractive index measurement. The device was set to monitor glucose concentration continuously in real time by measuring differential refractive index and calibrated by standard glucose solutions in a range of 0.1 to 1.0%. The possibility of industrial application of the device was demonstrated by real-time monitoring of glucose concentration in textile processing solutions such as desizing bath and cellulase treatment bath. Both of solutions contained glucose as a major degraded product. The device would be able to control the weight loss of cellulosic fiber during cellulase treatment since the amount of degraded products in a processing bath is proportional to its weight loss.