기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
CAM Zirconia 완전도재 구조물의 정밀 적합도에 관한 연구
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • CAM Zirconia 완전도재 구조물의 정밀 적합도에 관한 연구
  • A STUDY OF PRECISE FIT OF THE CAM ZIRCONIA ALL-CERAMIC FRAMEWORK
저자명
전미현,전영찬,정창모,임장섭,정희찬,Jeon. Mi-Hyeon,Jeon. Young-Chan,Jeong. Chang-Mo,Lim. Jang-Seop,Jeong. Hee-Chan
간행물명
대한치과보철학회지
권/호정보
2005년|43권 5호|pp.611-621 (11 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

State of problem: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. Purpose: This study was to evaluate the at of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). Material and Method: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesio-distal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of $ imes100$. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. Results and Conclusion: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia$(81.9{mu}m)$ and metal $(81.3{mu}m)$ framework and internal marginal gaps of zirconia $(44.6{mu}m)$ were smaller than those of metal framework $(58.6{mu}m)$. 2. Internal axial gaps of zirconia framework$(96.7{mu}m)$ were larger than those of metal frame-work$(78.1{mu}m)$ significantly and adversely, internal occlusal gaps of zirconia frame-work$(89.4{mu}m)$ were smaller than those of metal framework $(104.9{mu}m)$ significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.