- 화학발광법에 의한 수용액 중의 퀴닌 정량
- ㆍ 저자명
- 이현숙,김태연,최경혜,배현숙,이상학,Lee. Hyun-Sook,Kim. Tae-Yeon,Choi. Kyoung-Hye,Bae. Hyun-Sook,Lee. Sang-Hak
- ㆍ 간행물명
- 센서학회지
- ㆍ 권/호정보
- 2006년|15권 5호|pp.317-322 (6 pages)
- ㆍ 발행정보
- 한국센서학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
A method to determine quinine in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of quinine to a solution of lucigenin and hydrogen peroxide. The effects of KOH concentration, flow rate of reagents, $H_{2}O_{2}$ concentration used for the masking of quinine on the chemiluminescence intensity have been investigated. The calibration curve for quinine was linear over the range from $1.0{ imes}10^{-7}$ M to $1.0{ imes}10^{-3}$ M, coefficient of correlation was 0.993 and the detection limit was $3.0{ imes}10^{-8}$ M under the optimal experimental conditions of 1.0 M, 1.5 M, 3.0 mL/min for the concentration of $H_{2}O_{2}$, KOH and flow rate of reagents, respectively.