- Cycle Analysis on LNG Boil-off Gas Re-Liquefaction Plant
- Cycle Analysis on LNG Boil-off Gas Re-Liquefaction Plant
- ㆍ 저자명
- Chin. Y.W.
- ㆍ 간행물명
- 한국초전도·저온공학회논문지
- ㆍ 권/호정보
- 2006년|8권 4호|pp.34-38 (5 pages)
- ㆍ 발행정보
- 한국초전도저온공학회
- ㆍ 파일정보
- 정기간행물|ENG| PDF텍스트
- ㆍ 주제분야
- 기타
Cycle analysis was performed in order to find the optimum design point of the LNG Boil-off gas re-liquefaction system. Thermodynamic analysis revealed the system could be defined by three state variables. Thus the system performance could be described by the three cold endpoint temperatures of the three-pass heat exchanger. This enabled us to investigate the cycle performance in terms of the heat exchanger parameters. To get access to the cycle states of higher system performances, larger heat exchangers were found necessary. Also the thermal pinch in cryogenic heat exchangers was found to act as a limiting factor to the system performance.