기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Kyphotic Angle Measurement Accuracy for Vertebral Osteoporotic Compression Fracture; Reliable Method for Kyphotic Angle Measurement
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Kyphotic Angle Measurement Accuracy for Vertebral Osteoporotic Compression Fracture; Reliable Method for Kyphotic Angle Measurement
  • Kyphotic Angle Measurement Accuracy for Vertebral Osteoporotic Compression Fracture; Reliable Method for Kyphotic Angle Measurement
저자명
Hong. Jae-Taek,Lee. Sang-Won,Son. Byung-Chul,Sung. Jae-Hoon,Park. Choon-Keun,Kim. Moon-Chan
간행물명
Journal of Korean neurosurgical society
권/호정보
2006년|39권 4호|pp.256-259 (4 pages)
발행정보
대한신경외과학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Objective : Having a reliable and reproducible measurement technique to measure the sagittal contour in vertebral fractures is paramount to clinical decision making. This study is designed to determine the most reliable measurement technique in osteoporotic vertebral compression fracture. Methods : Fifteen lateral radiographs of thoracic and lumbar fractures were selected and measured on two separate occasions by three spine surgeons using six different measurement techniques [Centroid, Harrison Posterior Tangent Methods and 4 different types of modified Cobb method]. The radiograph quality was assessed and the center beam location was determined. Statistical analysis including ANOVA for repeated measures was carried out using the SAS software [v 8.0]. Results : The inter and intraobserver variance of the Cobb method 4 and Harrison posterior tangent method were significantly lower than the other four methods. The intraobserver correlation coefficients were the most consistent using the Cobb method 4 [0.982]. which was followed by the Harrison posterior tangent [0.953] and Cobb methods 1 [0.874]. The intraobserver agreement [% of repeated measures within 5 degrees of the original measurement] ranged from 42% to 98% for each technique for all three observers, with the Cobb method 4 showing the best agreement [97.8%] followed by the Harrison posterior tangent method [937%]. Conclusion : The Cobb method-4 and Harrison posterior tangent methods, when applied to measuring the kyphosis, are reliable and have a similar small error range. The Cobb method 4 shows the best overall reliability. However, the centroid method and Cobb method using a fractured endplate do not produce an accurate result due to inter and intraobserver differences in determining the baseline.