- 무창자돈사의 환경요인 개선을 위한 변형환기시스템의 현장 평가 연구
- ㆍ 저자명
- 김헌태,고한종,김기연,서진귀구,최홍림,Kim. H.T.,Ko. H.J.,Kim. K.Y.,Nishizu. T.,Choi. H.L.
- ㆍ 간행물명
- 바이오시스템공학
- ㆍ 권/호정보
- 2006년|31권 3호|pp.175-181 (7 pages)
- ㆍ 발행정보
- 한국농업기계학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Nursery pig building is imperative to provide environmental conditions favorable to maintenance of piglet health and the efficiency of growth rate. To meet the ultimate goal, it is necessary to apply proper ventilation design and construction to a confinement livestock building. This study was conducted to investigate the performance of a modified ventilation system in terms of devised slot-inlet (modification I) and exhaust fan (modification II) to improve air change rate in a confined nursery pig building, with dimension of 5.9 m(W) ${ imes}$ 12.6 m(L) ${ imes}$ 2.2 m(H) in an Darby Genetic Station. The experiment was carried out in August, especially when the outdoor peak temperature were above $30^{circ}C$ and the measured indoor environmental factors were temperature, air velocity, humidity and ammonia concentration which have been known to affect the piglet health and growth. There was no difference in indoor temperature between the original and modified ventilation systems, however the air velocity and ammonia concentration in confined nursery pig building with modified ventilation system were, in most cases, better performance than original ventilation system. Therefore, it was concluded that the slot-inlet system that kept indoor environmental factors pertinent and had an economic advantage, should be considered as a ventilation system for decreasing sensible heat from piglet in confined nursery pig building during extreme summer season.