- 히트파이프를 이용한 매스콘크리트의 수화열 제어에 관한 실험 연구
- ㆍ 저자명
- 백동일,BaeK. Dong-Il
- ㆍ 간행물명
- 韓國海洋工學會誌
- ㆍ 권/호정보
- 2007년|21권 6호|pp.81-86 (6 pages)
- ㆍ 발행정보
- 한국해양공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In order to eliminate the hydration heat of mass concrete, this paper reports the results of hydration heat control in mass concrete using the OCHP (Oscillating capillary tube heat pipe). In the summarized results of the mock up experiments, distributing the heat pipe at 300 mm intervals based on the center of the test specimen was the most effective. A 200 mm turn interval for the heat pipe was measured to be the most appropriate, taking into account the reinforcement placing at the actual site. Therefore, when the hydration heat control method using the heat pipe developed in this study is applied, not only canconstruction efficiency & a reduction in the necessary construction time be expected, but so can outstanding economical effects.