- 방전플라즈마소결법에 의해 제조된 저탄성 타이타늄 다공질체의 생체적합성 평가
- ㆍ 저자명
- 송호연,김영희,장세훈,오익현,Song. Ho-Yeon,Kim. Young-Hee,Chang. Se-Hun,Oh. Ik-Hyun
- ㆍ 간행물명
- 한국재료학회지
- ㆍ 권/호정보
- 2007년|17권 2호|pp.107-114 (8 pages)
- ㆍ 발행정보
- 한국재료학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Porous Ti compacts were fabricated by spark plasma sintering (SPS) method and their in vitro and in vivo biocompatibilities were investigated. Alkaline phosphatase (ALP) activity representing the activity of osteoblast was increased when osteoblast-like MG-63 cells were cultured on the Ti powder surface. Some genes related to cell growth were over-expressed through microarray analysis. The porous Ti compact with 32.2% of porosity was implanted in the subcutaneous tissue of rats to confirm in vivo cytotoxicity. 12 weeks post-operation, outer surface and inside the porous body was fully filled with fibrous tissue and the formation of new blood vessels were observed. No inflammatory response was confirmed. To investigate the osteoinduction, porous Ti compact was implanted in the femur of NZW rabbits for 4 months. Active in-growth of new bone from the surrounded compact bone was observed around the porous body. From the results, The porous Ti compacts fabricated by spark plasma sintering might be available for the application of the stem part of artificial hip joint.