- 서울시 일부 종합병원의 공기 중 미생물 농도 분포
- ㆍ 저자명
- 송주희,민진영,조경아,윤영희,백남원,Song. Ju-Hee,Min. Jin-Young,Jo. Kyung-A,Yoon. Young-Hee,Paik. Nam-Won
- ㆍ 간행물명
- 韓國環境保健學會誌
- ㆍ 권/호정보
- 2007년|33권 2호|pp.104-114 (11 pages)
- ㆍ 발행정보
- 한국환경보건학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study evaluated the airborne concentrations of bacteria, Gram-negative bacteria, and fungi in waiting rooms, wards, and outdoors, according to time and particle size between October 17 and November 28, 2003. The geometric mean number of airborne bacteria was highest in the morning. The more people there were, the higher was the total bacteria concentration. The concentration of fungi was also highest in the morning. Temperature and relative humidity affected the concentrations of fungi significantly (p<0.05). This study found relationships between microorganism concentrations and (actors such as time, place, temperature, humidity, ventilation, and number of people. Therefore, to manage the pollution resulting from airborne microorganisms, each time, place, and environmental factor should be examined periodically, and the number, size, and movement of airborne microorganisms should be evaluated.