기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY
  • ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY
저자명
Miyashita. Yuko,Suzuki. Hiroki,Kishi. Masataka,Ko. Sok-Min
간행물명
대한치과보철학회지
권/호정보
2007년|45권 3호|pp.389-400 (12 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{pm}0.016mm$ and $0.017{pm}0.022mm$, respectively and that of the conventional method was $0.017{pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.