기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Determination of Highly Soluble L-Carnitine in Biological Samples by Reverse Phase High Performance Liquid Chromatography with Fluorescent Derivatization
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Determination of Highly Soluble L-Carnitine in Biological Samples by Reverse Phase High Performance Liquid Chromatography with Fluorescent Derivatization
  • Determination of Highly Soluble L-Carnitine in Biological Samples by Reverse Phase High Performance Liquid Chromatography with Fluorescent Derivatization
저자명
Cao. Qing-Ri,Ren. Shan,Park. Mi-Jin,Choi. Yun-Jaie,Lee. Beom-Jin
간행물명
Archives of pharmacal research : a publication of the Pharmaceutical Society of Korea
권/호정보
2007년|30권 8호|pp.1041-1046 (6 pages)
발행정보
대한약학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

This study was performed in order to validate an effective high performance liquid chromatograpy (HPLC) method to determine L-carnitine in biological samples such as plasma, milk and muscle in cows. An L-carnitine derivative for fluorescence absorption was synthesized with 1-aminoanthracene (16 mg/mL in acetone) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDAC: 160 mg/mL in 0.01 M $NaH_2PO_4$ buffer) as a precolumn fluorescent derivative reagent. ${gamma}-Butyrobetaine$ HCI was used as an internal standard. A reversed-phase column with fluorescence detection at the excitation and emission wavelengths of 248 and 418 nm were used. The mobile phase consisted of 30% acetonitrile with 0.1 M ammonium acetate in water (pH 3.5) adjusted with acetic acid and delivered at a flow rate of 1.5 mL/min. The L-carnitine concentration in plasma, milk and muscle samples of cows after oral feeding with 24 g L-carnitine/day for 2 months was then determined. All biological samples were deproteinated by barium hydroxide and zinc sulfate heptahydrate before the derivative reaction. Blank cow plasma was dialyzed using cellulose membrane for standard calibration. The calibration curve showed good linearity ($r^2$ >0.999) over the concentration range of 50 to 5000 ng/mL. The precision and accuracy were also satisfactory with less than 15% intra- and inter- day coefficiency of variations. The peaks of L-carnitine and internal standard in HPLC chromatography were successfully separated in plasma, milk and muscle samples of cows. The current derivatization method of L-carnitine for fluorescence detection was simple and adequately sensitive and could be applied to determine L-carnitine in biological samples.