기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
DEGREE OF CONVERSION OF BIS-ACRYLIC BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • DEGREE OF CONVERSION OF BIS-ACRYLIC BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS
  • DEGREE OF CONVERSION OF BIS-ACRYLIC BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS
저자명
Kim. Sung-Hun,Watts. David C.
간행물명
대한치과보철학회지
권/호정보
2008년|46권 6호|pp.639-643 (5 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

STATEMENT OF PROBLEM: The degree of conversion may influence the ultimate mechanical and physical properties of provisional crown and fixed partial denture materials. The high levels of the unreacted residual monomer may cause deleterious effect on the properties. PURPOSE: The purpose of this study was to measure the degree of conversion of bis-acrylic based provisional crown and fixed partial denture materials by using an infrared spectroscopic method. MATERIAL AND METHODS: Chemically activated three bis-acrylic based provisional crown and fixed partial denture materials, LuxaTemp [DMG, Hamburg, Germany], fast set TemPhase [Kerr, Orange, CA, USA] and Protemp 3 Garant [3M-ESPE, St Paul, MN, USA], were investigated by Fourier transform infrared spectrometry (FTIR). The FTIR spectra of the materials tested were immediately obtained after mixing. The specimens were stored under dry conditions and at $23^{circ}C$ for 24 hours, and then the spectra of the materials were also obtained. The degree of conversion (%) was calculated from the spectrum of the absorbance between the aliphatic double bond at 1637 $cm^{-1}$ and the aromatic double bond at 1608 $cm^{-1}$ using the baseline method. The data were statistically analyzed using one-way ANOVA and the multiple comparison Scheffe test at the significance level of 0.05. RESULTS: The mean value and standard deviation of the degree of conversion were 52.5 % ${pm}$ 1.1 %, 50.3 % ${pm}$ 0.8 %, and 42.3 % ${pm}$ 4.9 % for LuxaTemp, Protemp 3 Garant and fast set TemPhase, respectively. There was no significant difference between LuxaTemp and Protemp 3 Garant, whereas there was a statistically difference between Protemp 3 Garant and fast set TemPhase, and LuxaTemp and fast set TemPhase (P < .05). CONCLUSION: The degree of conversion of fast set TemPhase was significantly lower than those of the others. The degree of conversion may be correlated with the rate of polymerization.