- 치은염 환자에서 저출력 이산화탄소 레이저의 염증완화 효과에 관한 연구
- ㆍ 저자명
- 송현종,김병옥,장현선,Song. Hyun-Jong,Kim. Byung-Ock,Jang. Hyun-Seon
- ㆍ 간행물명
- 대한치주과학회지
- ㆍ 권/호정보
- 2008년|38권 4호|pp.657-668 (12 pages)
- ㆍ 발행정보
- 대한치주과학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Purpose: In this study, we compared low-power $CO_2$ laser treatment to ultrasonic scaling, which is generally approved as a power-driven mechanical instrumentation, and evaluated both of these treatments regarding their clinical effectiveness and change in the volume of in GCF. Material and methods: 20 patients who had gingivitis were selected. all of patients has no systemic problems. Randomly selected, one quadrant received ultrasonic scaling only, another quadrant received ultrasonic scaling and $CO_2$ laser irradiation, the other quadrant received $CO_2$ laser irradiation only. Clinical parameters measured at baseline, 1 weeks, 2weeks, 4weeks and 8weeks. Result: Pocket probing depth and clinical attachment level were not changed during study period. Gingival index of all group were improved after treatment. At 1 weeks after treatment, Gingival index of ultrasonic scaling group was only significantly different compared to control group. At 2 weeks after treatment, gingival index of all experimental group were significantly different compared to control group. At 4 and 8 weeks after treatment, gingival index of all group were increased, but experimental group were lower than control group. Sulcus bleeding index was similar to the results of gingival index. At 1 weeks after treatment, all experimental group were significantly different compared to control group and it maintained during study. At 2 weeks after treatment, sulcus bleeding index of all group were lowest during study. Gingival crevicular fluid were measured with $Periotron^{(R)}$ 8000($Oraflow^{(R)}$, Inc. USA). At baseline, all group were showed moderately severe condition. At 1 week after treatment, laser treatment only group was reduced quantity of gingival crevicular fluid mostly, and all group were reduced quantity of gingival crevicular fluid. At 2 weeks after treatment, all group were health state. At 4 and 8 weeks after treatment, all group were showed recurrent of inflammation, and control group was the most significantly increased. Conclusion: This study showed that the effects of $CO_2$ laser treatment were similar to conventional ultrasonic scaling and this result remained longer than plaque control only. These results suggest possibility of $CO_2$ laser treatment for altered periodontal therapy.