- 수분사를 통한 마이크로터빈 성능향상 해석
- ㆍ 저자명
- 전무성,이종준,김동섭,Jeon. Mu-Sung,Lee. Jong-Jun,Kim. Tong-Seop
- ㆍ 간행물명
- 유체기계저널
- ㆍ 권/호정보
- 2009년|12권 2호|pp.46-51 (6 pages)
- ㆍ 발행정보
- 유체기계공업학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, generating hot water is usual method of heat recovery from microturbine CHP (combined heat and power) systems. The power of microturbines decreases as ambient temperature increases. This study predicted micoturbine power boost by injecting hot water generated by heat recovery. Influence of injecting water at two different locations was examined. Water injection improves power, but efficiency depends much on the injection location. Injecting water at the compressor discharge shows a much higher efficiency than the combustor injection. However, the combustor injection may have as much available cogeneration heat as the dry operation, while the available heat in the compressor discharge injection is much smaller than the dry operation.