기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary Study
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary Study
  • Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary Study
저자명
Choo. Ki-Seok,Lee. Tae-Hong,Choi. Chang-Hwa,Park. Kyung-Pil,Kim. Chang-Won,Kim. Suk
간행물명
Journal of Korean neurosurgical society
권/호정보
2009년|45권 5호|pp.284-288 (5 pages)
발행정보
대한신경외과학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Objective : Our retrospective study aimed to determine whether 16-slice computerized tomography (CT) angiography optimized sharp kernel is suitable for the evaluation of visibility, luminal patency and re-stenosis of intracranial stents in comparison with conventional angiography. Methods : Fifteen patients with symptomatic intracranial stenotic lesions underwent balloon expandable stent deployment of these lesions (10 middle cerebral arteries, 2 intracranial vertebral arteries, and 3 intracranial internal carotid arteries). CT angiography follow-up ranged from 6 to 15 months (mean follow-up, 8 months) after implantation of intracranial stents and conventional angiography was confirmed within 2 days. Curved multiplanar reformations with maximal intensity projection (MIP) with optimal window settings for assessment of lumen of intracranial stents were evaluated for visible lumen diameter, stent patency (contrast distal to the stent as an indirect sign), and re-stenosis by two experienced radiologists who blinded to the reports from the conventional angiography. Results : All of stents deployed into symptomatic stenotic lesions. All stents were classified as patent and no re-stenosis, which was correlated with results of conventional angiography. Parts of the stent lumen could be visualized in all cases. On average, 57% of the stent lumen diameter was visible using optimized sharp kernel. Significant improvement of lumen visualization (22%, p<0.01) was observed using the optimized sharp kernel compared with the standard sharp kernel. Inter-observer agreements on the measurement of lumen diameter and density were judged as good, respectively (p<0.05). Conclusion : Sixteen-slice CT using the optimized sharp kernel may provide a useful information for evaluation of lumen diameter patency, and re-stenosis of intracranial stents.