- 재생냉각시스템의 성능예측기법에 관한 실험적 연구
- ㆍ 저자명
- 정세용,이양석,Jung. Se-Yong,Lee. Yang-Suk
- ㆍ 간행물명
- 韓國軍事科學技術學會誌
- ㆍ 권/호정보
- 2009년|12권 3호|pp.396-405 (10 pages)
- ㆍ 발행정보
- 한국군사과학기술학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The experimental research was conducted to setup a performance prediction logic for the regenerative cooling system on a small scale liquid rocket engine using kerosene and LOX. Total heat flux of the combustion gas side was determined for the flow rate of the coolant, combustion pressure using the calorimeter thrust chamber. Based on the experimental investigation, a performance prediction scheme for the regenerative cooling system is setup in our own way. A performance prediction logic for the regenerative cooling system has been developed by the correction scheme of the combustion gas side. The key parameters determining the temperature limitation of the coolant are the mass flow rate of the coolant and the length of the combustion chamber and the nozzle. And the parameters to control the limitation of the usable wall temperature are the number of channels and wall thickness.