- 주위온도조건이 스터링 극저온냉동기의 성능에 미치는 영향
- ㆍ 저자명
- 홍용주,김효봉,박성제,Hong. Yong-Ju,Kim. Hyo-Bong,Park. Seong-Je
- ㆍ 간행물명
- 한국초전도·저온공학회논문지
- ㆍ 권/호정보
- 2009년|11권 3호|pp.65-68 (4 pages)
- ㆍ 발행정보
- 한국초전도저온공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The Stirling cryocoolers have been widely used for the cooling of the infrared detector(InSb, HgCdTe, and etc,) and HTS(High Temperature Superconductor) to the cryogenic temperature. The monobloc Stirling cryocoolers with the rotary compressor are applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. The typical performance factors of the Stirling cryocooler are the cool-down time, cooling capacity at the desired temperature (80 K), the electric input power and COP. The above performance factors depend on the operating conditions such as the charging pressure of the helium gas, the thermal environment and etc.. In this study, the effects of the thermal environment (temperature of 241, 293, and 333 K) on the performance of the cryocooler were investigated by experiments. The results show the effects of the temperature of the thermal environment on the cooling capacity and input power.