기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Pedicular and Extrapedicular Morphometric Analysis in the Korean Population : Computed Tomographic Assessment Relevance to Pedicle and Extrapedicle Screw Fixation in the Thoracic Spine
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Pedicular and Extrapedicular Morphometric Analysis in the Korean Population : Computed Tomographic Assessment Relevance to Pedicle and Extrapedicle Screw Fixation in the Thoracic Spine
  • Pedicular and Extrapedicular Morphometric Analysis in the Korean Population : Computed Tomographic Assessment Relevance to Pedicle and Extrapedicle Screw Fixation in the Thoracic Spine
저자명
Kim. Jun-Hak,Choi. Gyeong-Mi,Chang. In-Bok,Ahn. Sung-Ki,Song. Joon-Ho,Choi. Hyun-Chul
간행물명
Journal of Korean neurosurgical society
권/호정보
2009년|46권 3호|pp.181-188 (8 pages)
발행정보
대한신경외과학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Objective : To evaluate the anatomical parameters that must be considered when performing thoracic transpedicular or extrapedicular screw fixation. Methods : We selected 958 vertebrae (1,916 pedicles) from 98 patients for analysis. Eight parameters were measured from CT scans : the transverse outer pedicular diameter, transverse inner pedicular diameter, length, angle, chord length of the pedicles and the transverse width, angle, and chord length of the pedicle-rib units. Results : The age of the patients ranged from 21 to 82 years (mean: 48.2 years) and there were 57 men and 41 women. The narrowest transverse outer pedicular diameter was at T5 (4.4 mm). The narrowest pedicle length was at T1 (15.9 mm). For pedicle angle, T1 was 31.6 degrees, which was the most convergent angle, and it showed the tendency of the lower the level, the lesser the convergent angle. The chord length showed a horizontal pattern with similar values at all levels. For the PRU width, T5 showed a similar pattern to the pedicle width at 13.4 mm. For the PRU angle, T1 was the largest angle at 46.2 degrees and the tendency was the lower the level. the narrower the angle. For chord length, T1 was the shortest at 46.9 mm and T8 was the longest at 60.1 mm. Conclusion : When transpedicular screw fixations carried out at the mid-thoracic level, special care must be taken because there is a high chance of danger of medial wall violation. In these circumstances, extrapedicular screw fixation may be considered as an alternative treatment.