- 왕수분해와 결합한 자동분석법의 토양 중 불소시험 유효성 연구
- ㆍ 저자명
- 나경호,윤인철,이정복,Na. Kyung-Ho,Yun. In-Chul,Lee. Jung-Bok
- ㆍ 간행물명
- 지하수토양환경
- ㆍ 권/호정보
- 2010년|15권 5호|pp.8-15 (8 pages)
- ㆍ 발행정보
- 한국지하수토양환경학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The purpose of this research is to check the validation of an auto-analysis method combined with aqua regia digestion apparatus for improvement of water distillation method used as a fluorine test of soil. Fluorine contents of CaO used in the pretreatment course of water distillation method were 120 mg/kg ~ 5,064 mg/kg at the blank test, which was exceeded up to maximum 12.5 times of the soil standard, so it was estimated due to a effect of fluorine existing as impurities of CaO. The recovery test of the same samples indicated that water distillation method and auto-analysis method were 134.5mg/kg and 161.7mg/kg respectively, the recovery ratio of the latter was 16.8% higher than the formal. The validation test of two methods satisfied the standard, but auto analysis method was excellent more than distillation method. Also, auto analysis method could save a analysis time up to maximum 4.7 times by comparison with water distillation method.