- 삼각 분리 막대형 차압유량계 압력탭 조건이 유량 측정에 미치는 영향
- ㆍ 저자명
- 이충훈,Lee. Choong-Hoon
- ㆍ 간행물명
- 한국안전학회지
- ㆍ 권/호정보
- 2010년|25권 2호|pp.1-6 (6 pages)
- ㆍ 발행정보
- 한국안전학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Flow characteristics of differential pressure flow meters which have a shape of triangular separate bar (TSB) was investigated according to the machining conditions in pressure tapping holes. Diameter of the pressure taping holes is either 1.0 mm or 1.5 mm. Also, number of the pressure tapping holes are drilled either 9 or 17. The mass flow rate of the TSB flow meters are calibrated with a laminar flow meter by connecting them in line. The mass flow rate in the TSB flow meters are plotted with a non-dimensional parameter H which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters. An empirical correlation between the mass flow rate at the TSB flow meter and the non-dimensional parameter H was obtained. The empirical correlation showed highly linear relationship between the mass flow rate and the non-dimensional parameter H. The hole size of the pressure tapping holes has a bigger effect on the flow rate than the number of the tapping holes.