- 온실 내 토양소독을 위한 지중난방시스템의 지중 열전달 특성
- ㆍ 저자명
- 박경규,하유신,홍동혁,장승호,김진현,Park. Kyung-Kyoo,Ha. Yu-Shin,Hong. Dong-Hyuck,Jang. Seung-Ho,Kim. Jin-Hyun
- ㆍ 간행물명
- 바이오시스템공학
- ㆍ 권/호정보
- 2010년|35권 2호|pp.108-115 (8 pages)
- ㆍ 발행정보
- 한국농업기계학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study was conducted to estimate the optimum temperature and required time for soil sterilization when heated water was circulated through underground heating pipes in the greenhouse which solar heat was influenced to the temperature of soil during the summer day. Two different types of heating pipes were used for the experiment. One was a polyethylene pipe(XL) and the other was a corrugated ring shaped stainless steel pipe(STS). The results of the studies were summarized as follows; By measuring the thermal characteristics of the XL and STS, it was examined that the average temperature differences of the inlet and outlet were $8.5^{circ}C$ and $13.3^{circ}C$, the average flowrates were 15.3 L/min and 5.6 L/min, and the average radiation powers were 9.1 kW and 4.1 kW, respectively. As results of the regression analysis of underground temperatures, when average soil temperature was$35^{circ}C$, an average water temperature was $80^{circ}C$, and XL was used, it was estimated that the possible heat transfer distance, the required time for heat transfer and heat flux to reach the underground temperature of $60^{circ}C$ were 300 mm, 230 hours, and $7.57kW/m^2$, respectively.