기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Physical and chemical properties of experimental mixture of mineral trioxide aggregate and glass ionomer cement
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Physical and chemical properties of experimental mixture of mineral trioxide aggregate and glass ionomer cement
  • Physical and chemical properties of experimental mixture of mineral trioxide aggregate and glass ionomer cement
저자명
정유나,양소영,박범전,박영준,황윤찬,황인남,오원만,Jeong. Yu-Na,Yang. So-Young,Park. Bum-Jun,Park. Yeong-Joon,Hwang. Yun-Chan,Hwang. In-Nam,Oh. Won-Man
간행물명
大韓齒科保存學會誌
권/호정보
2010년|35권 5호|pp.344-352 (9 pages)
발행정보
대한치과보존학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

영문초록

연구목적: 본 연구의 목적은 glass ionomer cement (GIC)와 혼합한 mineral trioxide aggregate (MTA)의 경화 시간, 압축 강도, 용해도, pH를 평가하고 이것을 MTA, GIC, IRM, SuperEBA와 비교하는 것이다. 연구 재료 및 방법: 경화 시간과 압축 강도는 ISO 9917, 그리고 용해도는 ISO 6876 기준에 따라 측정하였다. pH는 고체시편 전용 전극이 연결된 pH meter를 이용하여 측정하였다. 결과: GIC와 혼합한 MTA의 경화시간은 MTA보다 유의하게 짧았으며 압축 강도는 7일간 모든 시점에서 다른 재료보다 유의하게 낮았다. GIC와 혼합한 MTA 중에서 1 : 1과 2 : 1 시편의 용해도는 다른 실험군보다 유의하게 높았다. 또한 GIC와 혼합한 MTA의 pH는 혼합직후 2-4의 범위에서 1일 후 5-7 사이로 증가하였다. 결론: GIC와 혼합한 MTA의 경화시간은 MTA에 비해 개선되었으나 압축강도 및 pH와 같은 다른 성질들은 MTA에 비해 오히려 열등한 것으로 밝혀졌다. 임상적 사용이 가능하려면, MTA의 기존 장점을 저해하지 않으면서 단점을 개선하기 위한 적절한 혼합비를 찾아내고 생체친화성을 평가하는 추가적인 연구가 필수적이다.

기타언어초록

Objectives: The purpose of this study was to determine the setting time, compressive strength, solubility, and pH of mineral trioxide aggregate (MTA) mixed with glass ionomer cement (GIC) and to compare these properties with those of MTA, GIC, IRM, and SuperEBA. Materials and Methods: Setting time, compressive strength, and solubility were determined according to the ISO 9917 or 6876 method. The pH of the test materials was determined using a pH meter with specified electrode for solid specimen. Results: The setting time of MTA mixed with GIC was significantly shorter than that of MTA. Compressive strength of MTA mixed with GIC was significantly lower than that of other materials at all time points for 7 days. Solubility of 1 : 1 and 2 : 1 specimen from MTA mixed with GIC was significantly higher than that of other materials. Solubility of 1 : 2 specimen was similar to that of MTA. The pH of MTA mixed with GIC was 2-4 immediately after mixing and increased to 5-7 after 1 day. Conclusions: The setting time of MTA mixed with GIC was improved compared with MTA. However, other properties such as compressive strength and pH proved to be inferior to those of MTA. To be clinically feasible, further investigation is necessary to find the proper mixing ratio in order to improve the drawbacks of MTA without impairing the pre-existing advantages and to assess the biocompatibility.