- 유공벽을 이용한 우류식 염소접촉조 사류 저감 방안 연구
- ㆍ 저자명
- 박현오,박노석,차민환,김사동,원찬희,Park. Hyun-Ho,Park. No-Suk,Cha. Min-Whan,Kim. Sa-Dong,Won. Chan-Hee
- ㆍ 간행물명
- 上下水道學會誌
- ㆍ 권/호정보
- 2010년|24권 5호|pp.519-525 (7 pages)
- ㆍ 발행정보
- 대한상하수도학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
From the results of tracer test for the existing chlorine contactor in Y water treatment plant, $T_{10}$ and $T_{10}$/T were calculated as 130 min and 0.16, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by T10 and $T_{10}$/T, and disinfection performance. In this study, in order to reduce dead zone within contactor, the installation of porous baffles in the near of each corner was suggested and verified using transient CFD(Computational Fluid Dynamics) simulation technique and tracer tests on dynamic condition. From the results of simulation and tracer tests, it was revealed that porous baffles installed have been effective to reduce dead zone within contactor, and increase plug flow fraction.