- 버터플라이 밸브의 유량측정 불확도에 대한 영향
- ㆍ 저자명
- 윤석호,이정호,유청환,박상진,정장환,Yoon. Seok-Ho,Lee. Jung-Ho,Yu. Cheong-Hwan,Park. Sang-Jin,Chung. Chang-Hwan
- ㆍ 간행물명
- 유체기계저널
- ㆍ 권/호정보
- 2010년|13권 4호|pp.18-24 (7 pages)
- ㆍ 발행정보
- 유체기계공업학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
For testing large-capacity pumps, the accurate flow rate measurement is needed in the test loop. As a measuring method of flow rate, venturi tube is recommended due to its low pressure loss. However, upstream disturbance of loop component such as a valve has an effect upon the accuracy of flow rate measurement. For controlling flow rate in case of high flow rate and large-scale piping system, a butterfly-type valve is generally used due to its compactness. However, a butterfly valve disturbs downstream flow by generating turbulence, cavities, or abrupt pressure change. In this study, the effect of downstream disturbance of butterfly valve on the flow rate measurement using a venturi tube is investigated. Test loop consists of circulation pump, reservoir, butterfly valve, venturi tube, and reference flow meter. The test is conducted with regard to a different valve opening angle of butterfly valve. According to the valve opening angle, the uncertainty of flow rate measurement is investigated.