- 상하악 동시 악교정수술에서 흡수성 고정판을 이용한 골편고정시 술후 안정성에 대한 연구
- ㆍ 저자명
- 박정민,박영욱,Park. Jung-Min,Park. Young-Wook
- ㆍ 간행물명
- 대한악안면성형재건외과학회지
- ㆍ 권/호정보
- 2010년|32권 2호|pp.126-131 (6 pages)
- ㆍ 발행정보
- 대한악안면성형재건외과학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Objectives: This study is aimed to determine any differences in the postoperative stability between absorbable and titanium plate systems for fixation in orthognathic surgery with simultaneous maxillomandibular procedures especially including maxillary posterior impaction and advancement. Study Design: Forty patients with dentofacial deformities were randomly assigned into titanium (4 males and 6 females) and absorbable (17 males and 13 females) fixation group. All patients had undergone surgical alterations of maxilla with posterior impaction and advancement. A comparison study of the change in the maxillary position after the simultaneous surgery was performed with 1-day, 6-months postoperative lateral cephalograms compared to preoperative lateral cephalogram by tracing. Wilcoxon rank sum test was used for statistical analysis. Result: The position of the maxilla was stable after surgery and was not changed significantly from 1 day to 6 month after the simultaneous maxillomandibular surgery both in the experimental (absorbable plates) and control (titanium plates). Conclusion: This study suggests that application of absorable plating system in the fixation of maxillary segment in the simultaneous maxillomandibular procedures, leads to a predictable short-term postoperative skeletal stability comparable to the titanium plating system. Long term follow-up and further studies will be needed.