Assistance of the elbow flexion motion on the active elbow orthosis using muscular stiffness force feedback
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Assistance of the elbow flexion motion on the active elbow orthosis using muscular stiffness force feedback
  • Assistance of the elbow flexion motion on the active elbow orthosis using muscular stiffness force feedback
저자명
Kim. Kyung,Hong. Kyung-Ju,Kim. Nam-Gyun,Kwon. Tae-Kyu
간행물명
Journal of mechanical science and technology
권/호정보
2011년|25권 12호|pp.3195-3203 (9 pages)
발행정보
대한기계학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

An elbow orthosis with pneumatic artificial muscles has been developed to assist and enhance upper limbs movements and has been examined for effectiveness. The effectiveness of the elbow orthosis was examined by comparing muscular activities during alternate dumbbell curl motion wearing and without wearing the orthosis. The subjects participating in the experiment were young adults in their twenties. The subjects were instructed to perform a dumbbell curl motion in a sitting position with and without wearing an orthosis in turn, and a dynamometer was used to measure elbow joint torque in isokinetic mode. The measurements were done with four various dumbbell loads: 0, 1, 3, and 5 kg. We examined the effectiveness of the elbow orthosis in two control methods. First, the orthosis was pneumatically actuated and controlled in the passive control mode. Then, it was controlled in the active control mode using the muscular stiffness force of the muscle that is measured from a force sensor through a cDAQ-9172 board. For the analysis of muscular power, the muscular activities of the subject were measured during alternate dumbbell curl motion using MP150 (BIOPAC Systems, Inc.). The muscles of interest were biceps brachii muscle, triceps brachii muscle, brachioradialis muscle, and flexor carpi ulnaris muscle in the upper limbs of the right side. The elbow joint torque was measured during elbow flexion motion using a dynamometer at $60^{circ}$ per second for isokinetic strength. The experimental result showed that the muscular activities wearing the elbow orthosis were reduced and elbow joint torque wearing the elbow orthosis was higher because of the assist of the orthosis. As a result of this experiment, the effectiveness of the developed elbow orthosis was confirmed and the level of assistance was quantified. With this, we confirmed the effectiveness of the developed elbow orthosis.