Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
  • Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
저자명
Lee. Chong-Guk,Park. Hyang-Mi,Shin. Hye-Jung,Moon. Jin-Soo,Hong. Young-Mi,Kim. Nam-Soo,Ha. Il-Soo,Chang. Myeong-Jin,Oh. Kyeong-W
간행물명
Korean journal of pediatrics
권/호정보
2011년|54권 11호|pp.463-469 (7 pages)
발행정보
대한소아과학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Purpose: To validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol. Methods: Forty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and BHS protocols for children and adolescents. Each subject underwent 7 sequential BP measurements alternatively with a mercury sphygmomanometer and the test device by trained nurses. The results were analyzed according to the validation criteria of ESH-IP2. Results: The mean (${pm}SD$) difference in the absolute BP values between test device and mercury sphygmomanometer readings was $1.85{pm}1.65$ mmHg for systolic BP (SBP) and $4.41{pm}3.53$ mmHg for diastolic BP (DBP). These results fulfilled the Association for the Advancement of Medical Instrumentation criterion of a mean${pm}$SD below $5{pm}8$ mmHg for both SBP and DBP. The percentages of test device-observer mercury sphygmomanometer BP differences within 5, 10, and 15 mmHg were 96%, 100%, and 100% for SBP, and 69%, 92%, and 100% for DBP, respectively, in the part 1 analysis; both SBP and DBP passed the part 1 criteria. In the part 2 analysis, SBP passed the criteria but DBP failed. Conclusion: Although the Dinamap ProCare 200 BP monitor failed an adapted ESH-IP2, SBP passed. When comparing BP readings measured by oscillometers and mercury sphygmomanometers, one has to consider the differences between them, particularly in DBP, because DBP can be underestimated.