- 기둥(Post)과 핵(Core)의 이종재료 조합에 의한 치아의 유한요소해석
- ㆍ 저자명
- 강민규,탁승민,이석순,서민석,김효진,Kang. Min-Kyu,Tak. Seung-Min,Lee. Seok-Soon,Seo. Min-Seock,Kim. Hyo-Jin
- ㆍ 간행물명
- 한국정밀공학회지
- ㆍ 권/호정보
- 2011년|28권 4호|pp.474-481 (8 pages)
- ㆍ 발행정보
- 한국정밀공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the finite element stress analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia crown were prepared. Each model contained cortical bone, trabecular bone, periodontal ligament, 4mm apical root canal filling, and post-and-core. A 50N static occlusal load was applied to the palatal surface of the crown with a $60^{circ}$ angle to the long axis of the tooth. And three parallel type post (zirconia, glass fiber and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. For the Result of the research, the model applied glass fiber to post material has lowest von Mises stress and it is suitable for material of post core systems.