기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Safety and Efficacy of Transluminal Balloon Angioplasty Using a Compliant Balloon for Severe Cerebral Vasospasm after an Aneurysmal Subarachnoid Hemorrhage
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Safety and Efficacy of Transluminal Balloon Angioplasty Using a Compliant Balloon for Severe Cerebral Vasospasm after an Aneurysmal Subarachnoid Hemorrhage
  • Safety and Efficacy of Transluminal Balloon Angioplasty Using a Compliant Balloon for Severe Cerebral Vasospasm after an Aneurysmal Subarachnoid Hemorrhage
저자명
Choi. Beam-Jin,Lee. Tae-Hong,Lee. Jae-Il,Ko. Jun-Kyeung,Park. Hwa-Seung,Choi. Chang-Hwa
간행물명
Journal of Korean neurosurgical society
권/호정보
2011년|49권 3호|pp.157-162 (6 pages)
발행정보
대한신경외과학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Objective : Vasospasm of cerebral vessels remains a major source of morbidity and mortality after an aneurysmal subarachnoid hemorrhage (SAH). The purpose of this study was to evaluate the safety and efficacy of transluminal balloon angioplasty (TBA) for SAH-induced vasospasm. Methods : Eleven patients with an angiographically confirmed significant vasospasm (>50% vessel narrowing and clinical deterioration) were studied. A total of 54 vessel segments with significant vasospasm were treated by TBA. Digital subtraction angiography was used to confirm the presence of vasospasm, and TBA was performed to dilate vasospastic arteries. Medical and angiographic reports were reviewed to determine technical efficacy and for procedural complications. Results : TBA using Hyper-Glide or Hyper-Form balloons (MicroTherapeutics, Irvine, CA) was successfully accomplished in 88.9% vasospastic segments (48 of 54), namely, in the distal internal carotid artery (100%, n=7), the middle cerebral artery (100%), including the M1 (n=10), M2 (n=10), and M3 segments (n=4), in the vertebral artery (100%, n=2), basilar artery (100%, n=1), and in the anterior cerebral artery (ACA), including the A1 (66%), A2 (66%), and A3 segments (100%). Vessel diameters significantly increased after TBA. There were no cases of vessel rupture or thromboembolic complications. GCS at one day after TBA showed an improvement in all patients except one. Conclusion : This study suggests that TBA using Hyper-Glide or Hyper-Form balloons is a safe and effective treatment for subarachnoid hemorrhage-induced cerebral vasospasm.