- 상하좌우 복합유동 유도를 통한 고효율 HVM 마이크로 믹서 설계에 관한 연구
- ㆍ 저자명
- 유원설,김성진,강석훈,김판근,박상후,Yoo. Won-Sui,Kim. Sung-Jin,Kang. Seok-Hoon,Kim. Pan-Guen,Park. Sang-Hu
- ㆍ 간행물명
- 한국정밀공학회지
- ㆍ 권/호정보
- 2011년|28권 6호|pp.751-757 (7 pages)
- ㆍ 발행정보
- 한국정밀공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Subminiature devices such as Lab-on-a-chip and p-TAS(Micro Total Analysis System) have been intensively studied in biotechnology and chemistry, In many cases, a micromixer was widely used to mix different solutions for synthesizing novel materials. However, in microfluidic system, there is generally a laminar flow under very small Reynolds number so it is difficult to mix each solution perfectly. To settle this problem, we propose a new mixing mechanism which generates a horizontal and vertical multi-mixing (HVM) flow for effective mixing within a short mixing section. We evaluated the proposed mechanism using CFD analysis, and the results showed that the HVM mechanism had a relative high-effectiveness comparing to the existing methods.