기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection
  • Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection
저자명
Suh. Joon-Hyuk,Yang. Dong-Hyug,Lee. Byung-Kyu,Eom. Han-Young,Kim. Un-Yong,Kim. Jung-Hyun,Lee. Hye-Yeon,Han. Sang-Beom
간행물명
Bulletin of the Korean Chemical Society
권/호정보
2011년|32권 8호|pp.2648-2656 (9 pages)
발행정보
대한화학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

A simple HPLC-DAD method was developed and validated to determine B group vitamin content (thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxine and folic acid) in supplemented food samples, i.e., infant formula, cereal, low-calorie food, a multi-vitamin pill and a vitamin drink. In this study, the most significant advantages were simultaneous determination of the six B group vitamins in various food matrices and a small number of sample treatment steps that required only an organic solvent, acetonitrile. Moreover, this method prevents reduction of column durability, because the mobile phase does not contain ion-pairing reagents. Analytes were separated on a Develosil RPAQUEOUS $C_{30}$ (4.6 mm ${ imes}$ 250 mm, 5 ${mu}M$ particle size) column with a gradient elution of acetonitrile and 20 mM phosphate buffer (pH 3.0) at a flow rate between 0.8 and 1.0 mL/min. Detection was performed at 275 nm, except for that of pantothenic acid (205 nm). The calibration curves for all six vitamins showed good linearity with correlation coefficients ($r^2$) higher than 0.995. The developed method was validated with respect to linearity, intra- and inter-day accuracy and precision, limit of quantification (LOQ), recovery and stability. The method showed good precision and accuracy, with intra- and inter-assay coefficients of variation less than 15% at all concentrations. The recovery was carried out according to the standard addition procedure, with yields ranging from 89.8 to 104.4%. This method was successfully applied to the determination of vitamin B groups in supplemented food products.