Investigation of the mechanical behavior of a flexible solid metal seal for a cryogenic butterfly valve
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Investigation of the mechanical behavior of a flexible solid metal seal for a cryogenic butterfly valve
  • Investigation of the mechanical behavior of a flexible solid metal seal for a cryogenic butterfly valve
저자명
Ahn. Jun-Tae,Lee. Kyung-Chul,Lee. Kwon-Hee,Han. Seung-Ho
간행물명
Journal of mechanical science and technology
권/호정보
2011년|25권 9호|pp.2393-2400 (8 pages)
발행정보
대한기계학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Seat tightness at the fully shut position should be a consideration in the development of a butterfly valve for use in a liquefied natural gas (LNG) vessel. A flexible solid metal seal offers sufficient tightness of the butterfly valve and meets the specifications for cryogenic temperature. In the present study, characteristics for a cryogenic butterfly valve, such as the flow coefficient and the pressure loss coefficient, were estimated by numerical fluid analysis carried out to simulate 3-D flow and to study performance as it was affected by the opening angles of the valve disc. A design criterion to ensure the seat tightness of the butterfly valve at the fully shut position was proposed, in which the contact pressure between the metal seal and the valve disc would be compared with the fluid pressure. Numerical structural analysis showed that the contact pressure can be calculated by simulation of the frictional contact behavior on the surface of the metal seal and the valve disc. As a result, an adequate flexibility of the metal seal and the valve disc was required in order to accomplish a contact pressure that would be high enough to satisfy the seat tightness requirement. Under cryogenic temperature, thermal shrinkage caused the metal seal to adhere closely to the valve disc periphery at both sides and raised the contact pressure to a relatively high value, though there was no contact across a small area at the center position, which is susceptible to leakage. An additional displacement of the metal seal and the valve disc appeared at an operating fluid pressure of 6.9 bar and produced sufficient contact pressure at the no-contact area. This was verified by experimental leakage tests performed at room and cryogenic temperatures.