기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
한국형 소프트웨어를 이용한 유류.중금속 복합오염지역의 인체위해성평가 및 RBCA Tool Kit과의 비교분석
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 한국형 소프트웨어를 이용한 유류.중금속 복합오염지역의 인체위해성평가 및 RBCA Tool Kit과의 비교분석
저자명
남택우,류혜림,김영진,고석오,백기태,남경필,Nam. Taek-Woo,Ryu. Hye-Rim,Kim. Young-Jin,Ko. Seok-Oh,Baek. Ki-Tae,Nam. Kyoung-Phile
간행물명
지하수토양환경
권/호정보
2011년|16권 1호|pp.32-41 (10 pages)
발행정보
한국지하수토양환경학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

By using a newly developed Korean risk-based corrective action (K-RBCA) software (K-RBCA) and the RBCA Tool Kit, risk assessment was performed on a site that was contaminated with aromatic hydrocarbons and heavy metals. Eight chemicals including benzene, ethylbenzene, xylenes, naphthalene, benz(a) anthracene, benzo(b) fluoranthene, benzo(a) pyrene, and arsenic that exceeded the US EPA Soil Screening Level were chosen as the target pollutants. A conceptual site model was constructed based on the site-specific effective exposure pathways. According to the RBCA Tool Kit the carcinogenic risk of arsenic was larger than $10^{-6}$, which is the generally acceptable carcinogenic risk level. The K-RBCA estimated the same level of carcinogenic risk for arsenic. With the RBCA Tool Kit, the carcinogenic risk of benzo(a) pyrene was estimated to be about $1.3{ imes}10^{-6}$. However, with the K-RBCA benzo(a) pyrene did not exhibit any risk. The inconsistency between the softwares was attributed to the different fundamental settings (i.e., medium division) between the two softwares. While the K-RBCA divides medium into surface soil, subsurface soil, and groundwater, the RBCA Tool Kit divides medium into only soil and groundwater. These differences lead to the different exposure pathways used by the two softwares. The K-RBCA considers the exposure pathways in surface soil and subsurface soil separately to estimate risk, however, the RBCA Tool Kit considers the surface soil and subsurface soil as one and uses the integrated exposure pathways to estimate risk. Thus the resulting risk is higher when the RBCA Tool Kit is used than when the K-RBCA is used. The results from this study show that there is no significant difference in the risks estimated by the two softwares, thus, it is reasonable to use the K-RBCA we developed in risk assessment of soil and groundwater. In addition, the present study demonstrates that the assessor should be familiar with the characteristics of a contaminated site and the assumptions used by a risk assessment software when carrying out risk assessment.