  • Finite Element Analysis and the Clinical Consideration for the Methodology of PMMA Injection in Vertebroplasty
  • Finite Element Analysis and the Clinical Consideration for the Methodology of PMMA Injection in Vertebroplasty
저자명
Chae. Soo-Won,Lee. Moon Kyu,Park. Jung Yul,Lee. Tae Soo,Park. Sang Baek
간행물명
International journal of precision engineering and manufacturing
권/호정보
2012년|13권 8호|pp.1467-1472 (6 pages)
발행정보
한국정밀공학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Vertebroplasty is one of the most effective medical treatments for the collapse of the vertebral body. A general approach used for vertebroplasty is the polymethyl-methacrylate (PMMA) injection method, which involves injection at both sides of the vertebrate and allowing it to discharge via an end hole at the apical end of the injection needle. However, some patients that have received vertebroplasty through the method with some problems such as PMMA leakage and thermal emission; thus, there is a need to develop a new injection method. Accordingly, in this study we developed a method to inject PMMA into the upper end of the central vertebral body using an improved injector with a side-hole and discussed the clinical consideration. Prior to conducting a clinical study to test the improved instrument, the newly developed method was tested by performing finite element analysis at different PMMA injection: the single PMMA injection and both-sided injection. In this analysis, a single injection at the center of vertebral body was shown to yield a displacement of 0.15 mm, while the displacement for an injection at both sides was 0.24 mm. The combined results of this study suggest that the best place for injection was at the center (top-front) of the vertebral body. In addition, a clinical study on vertebroplasty using the existing end-hole injector and the newly developed side-hole injector was performed 6 months after operation. In these studies, a single PMMA injection was conducted on the upper part of the central vertebral body and the compressed and transformed vertebral body prior to treatment was restored after treatment. In addition, there was relatively little leakage of PMMA to peripheral regions. Therefore, it is expected that a PMMA injection on a single side in an accurate region using the improved injector will aid to reduce existing complications and sequelae.