- 수절환 및 냉매절환방식에 따른 지열히트펌프의 냉방특성에 관한 연구
- ㆍ 저자명
- 차동안,권오경,박차식,Cha. Dong-An,Kwon. Oh-Kyung,Park. Cha-Sik
- ㆍ 간행물명
- 설비공학논문집
- ㆍ 권/호정보
- 2012년|24권 8호|pp.605-611 (7 pages)
- ㆍ 발행정보
- 대한설비공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The objective of this study is to investigate the influence of the cooling performance for a water-to-water 10 RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The cooling capacity and refrigerant mass flow rate of the heat pump increased with increasing ground heat source temperature. But COP of the heat pump decreased with increasing ground heat source temperature. As a result, the water switching method with counter flow, compared to a refrigerant switching method, improves the cooling capacity and COP by approximately 6~9% in average, respectively.