- 고압전동기 고정자 권선의 온도변화에 따른 절연특성 분석
- ㆍ 저자명
- 공태식,주영호,김희동,박태성,Kong. Tae-Sik,Ju. Young-Ho,Kim. Hee-Dong,Park. Tae-Sung
- ㆍ 간행물명
- 전기전자재료학회논문지
- ㆍ 권/호정보
- 2012년|25권 10호|pp.786-790 (5 pages)
- ㆍ 발행정보
- 한국전기전자재료학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
A variety of diagnostic tests are widely applied in the field in industry to evaluate the condition of high voltage (HV) motor stator insulation. In this paper, the influence of temperature on the stator insulation diagnostic tests such as the insulation resistance, AC current, dissipation factor, and partial discharge measurements are studied and reported. The tests are performed with the HV motor stator winding temperature set between $40^{circ}C$ to $80^{circ}C$ in $10^{circ}C$ intervals. It is shown that the AC current, dissipation factor, and partial discharge magnitude steadily increase with temperature, which suggests that temperature must be taken into account in the interpretation of the test results.