- 추가적인 센서가 필요 없는 3상 PWM 인버터의 LCL 필터 능동댐핑
- ㆍ 저자명
- 안병웅,신희근,김학원,조관열,한병문,An. Byoung-Woong,Shin. Hee-Keun,Kim. Hag-Wone,Cho. Kwan-Yuhl,Han. Byoung-Moon
- ㆍ 간행물명
- 전력전자학회 논문지
- ㆍ 권/호정보
- 2013년|18권 1호|pp.10-17 (8 pages)
- ㆍ 발행정보
- 전력전자학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this paper, a new active damping method of LCL filter without capacitor voltage sensors is proposed for 3 phase PWM Inverter. Normally, L filter or LCL filter is used as an output filter of grid connected PWM inverter. An LCL filter has more excellent performance than L filter to reduce harmonic current, so the small inductance value can be used. However, the resonance problem in LCL filter is happen due to the zero impedance by the addition of LC branch. To solve the resonance problem, the various active damping method has been proposed so far. Generally, the virtual resistor active damping methods is required to additional hardware sensors for measurement of capacitor voltage and current. In this paper, the new active damping method is proposed without any capacitor voltage or current sensors. In the proposed method, the resonance component of the capacitor voltage of LCL filter can be observed by a simple MRAS(Model Reference Adaptive System) observer without additional hardware sensors, and this component is suppressed by feedforward compensation. The validity of the proposed method is proven by simulation and experiment on the 3-phase PWM inverter system.