기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Biodistribution of 99mTc Labeled Integrin Antagonist
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Biodistribution of 99mTc Labeled Integrin Antagonist
  • Biodistribution of 99mTc Labeled Integrin Antagonist
저자명
Jang. Beom-Su,Park. Seung-Hee,Shin. In Soo,Maeng. Jin-Soo,Paik. Chang H.
간행물명
Toxicological research
권/호정보
2013년|29권 1호|pp.21-25 (5 pages)
발행정보
한국독성학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The selective targeting of an integrin ${alpha}_v{eta}_3$ receptor using radioligands may enable the assessment of angiogenesis and integrin ${alpha}_v{eta}_3$ receptor status in tumors. The aim of this research was to label a peptidomimetic integrin ${alpha}_v{eta}_3$ antagonist (PIA) with $^{99m}Tc(CO)_3$ and to test its receptor targeting properties in nude mice bearing receptor-positive tumors. PIA was reacted with tris-succinimidyl aminotriacetate (TSAT) (20 mM) as a PIA per TSAT. The product, PIA-aminodiacetic acid (ADA), was radiolabeled with $[^{99m}Tc(CO)_3(H_2O)_3]^{+1}$, and purified sequentially on a Sep-Pak C-18 cartridge followed by a Sep-Pak QMA anion exchange cartridge. Using gradient C-18 reverse-phase HPLC, the radiochemical purity of $^{99m}Tc(CO)_3$-ADA-PIA (retention time, 10.5 min) was confirmed to be > 95%. Biodistribution analysis was performed in nude mice (n = 5 per time point) bearing receptor-positive M21 human melanoma xenografts. The mice were administered $^{99m}Tc(CO)_3$-ADA-PIA intravenously. The animals were euthanized at 0.33, 1, and 2 hr after injection for the biodistribution study. A separate group of mice were also co-injected with 200 ${mu}g$ of PIA and euthanized at 1 hr to quantify tumor uptake. $^{99m}Tc(CO)_3$-ADA-PIA was stable in phosphate buffer for 21 hr, but at 3 and 6 hr, 7.9 and 11.5% of the radioactivity was lost as histidine, respectively. In tumor bearing mice, $^{99m}Tc(CO)_3$-ADA-PIA accumulated rapidly in a receptor-positive tumor with a peak uptake at 20 min, and rapid clearance from blood occurring primarily through the hepatobiliary system. At 20 min, the tumor-to-blood ratio was 1.8. At 1 hr, the tumor uptake was 0.47% injected dose (ID)/g, but decreased to 0.12% ID/g when co-injected with an excess amount of PIA, indicating that accumulation was receptor mediated. These results demonstrate successful $^{99m}TC$ labeling of a peptidomimetic integrin antagonist that accumulated in a tumor via receptor-specific binding. However, tumor uptake was very low because of low blood concentrations that likely resulted from rapid uptake of the agent into the hepatobiliary system. This study suggests that for $^{99m}Tc(CO)_3$-ADA-PIA to be useful as a tumor detection agent, it will be necessary to improve receptor binding affinity and increase the hydrophilicity of the product to minimize rapid hepatobiliary uptake.