기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Reliability and Validity of the Postural Balance Application Program Using the Movement Accelerometer Principles in Healthy Young Adults
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Reliability and Validity of the Postural Balance Application Program Using the Movement Accelerometer Principles in Healthy Young Adults
  • Reliability and Validity of the Postural Balance Application Program Using the Movement Accelerometer Principles in Healthy Young Adults
저자명
Park. Seong-Doo,Kim. Ji-Seon,Kim. Suhn-Yeop
간행물명
한국전문물리치료학회지
권/호정보
2013년|20권 2호|pp.52-59 (8 pages)
발행정보
한국전문물리치료학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The purpose of this study was to determine the reliability and validity of the postural balance program which uses the movement accelerating field principles of posture balance training and evaluation equipment and smartphone movement accelerometer program (SMAP) in healthy young adults. A total of 34 people were appointed as the subject among the healthy young adults. By using Biodex stability system (BSS) and SMAP on the subject, the posture balance capability was evaluated. For the test-retest reliability, SMAP showed the intra-class correlation (ICC: .62~.91) and standard error measurement (SEM: .01~.08). BSS showed the moderate to high reliability of ICC (.88~.93) and SEM (.02~.20). In the reliability of inter-rater, ICC (.59~.73) as to SMAP, showed the reliability of moderate in eyes open stability all (EOSA), eyes open stability anterior posterior (EOSAP), eyes open stability medial lateral (EOSML) and eyes open dinamic all (EODA), eyes open danamic anterior posterior (EODAP), and eyes open danamic medial lateral (EODML). However, ICC showed reliability which was as low as .59 less than in other movements. In addition, BSS showed the reliability of high as ICC (.70~.75). It showed reliability which was as low as ICC (.59 less than) in other movements. In correlation to the balance by attitudes between SMAP and BSS, EOSML (r=.62), EODA (r=.75), EODML (r=.72), ECDAP (r=.64), and ECDML (r=.69) shown differ significantly (p<.05). However, the correlation noted in other movements did not differ significantly. Therefore, SMAP and BSS can be usefully used in the posture balance assessment of the static and dynamic condition with eyes opened and closed.