기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
A Rapid Method for Estimating the Levels of Urinary Thiobarbituric Acid Reactive Substances for Environmental Epidemiologic Survey
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • A Rapid Method for Estimating the Levels of Urinary Thiobarbituric Acid Reactive Substances for Environmental Epidemiologic Survey
  • A Rapid Method for Estimating the Levels of Urinary Thiobarbituric Acid Reactive Substances for Environmental Epidemiologic Survey
저자명
Kil. Han-Na,Eom. Sang-Yong,Park. Jung-Duck,Kawamoto. Toshihiro,Kim. Yong-Dae,Kim. Heon
간행물명
Toxicological research
권/호정보
2014년|30권 1호|pp.7-11 (5 pages)
발행정보
한국독성학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Malondialdehyde (MDA), used as an oxidative stress marker, is commonly assayed by measuring the thiobarbituric acid reactive substances (TBARS) using HPLC, as an indicator of the MDA concentration. Since the HPLC method, though highly specific, is time-consuming and expensive, usually it is not suitable for the rapid test in large-scale environmental epidemiologic surveys. The purpose of this study is to develop a simple and rapid method for estimating TBARS levels by using a multiple regression equation that includes TBARS levels measured with a microplate reader as an independent variable. Twelve hour urine samples were obtained from 715 subjects. The concentration of TBARS was measured at three different wavelengths (fluorescence: ${lambda}-_{ex}$ 530 nm and ${lambda}-_{em}$ 550 nm; ${lambda}-_{ex}$ 515 nm and ${lambda}-_{em}$ 553 nm; and absorbance: 532 nm) using microplate reader as well as HPLC. 500 samples were used to develop a regression equation, and the remaining 215 samples were used to evaluate the validity of the regression analysis. The induced multiple regression equation is as follows: TBARS level (${mu}M$) = -0.282 + 1.830 ${ imes}$ (TBARS level measured with a microplate reader at the fluorescence wavelengths ${lambda}-_{ex}$ 530 nm and ${lambda}-_{em}$ 550 nm, ${mu}M$) -0.685 ${ imes}$ (TBARS level measured with a microplate reader at the fluorescence wavelengths ${lambda}-_{ex}$ 515 nm and ${lambda}-_{em}$ 553 nm, ${mu}M$) + 0.035 ${ imes}$ (TBARS level measured with a microplate reader at the absorbance wavelength 532 nm, ${mu}M$). The estimated TBARS levels showed a better correlation with, and are closer to, the corresponding TBARS levels measured by HPLC compared to the values obtained by the microplate method. The TBARS estimation method reported here is simple and rapid, and that is generally in concordance with HPLC measurements. This method might be a useful tool for monitoring of urinary TBARS level in environmental epidemiologic surveys with large sample sizes.