- 제조시점에 따른 섬유상 흡음재의 물리적 특성 변화
- ㆍ 저자명
- 정영선,김경우,Jeong. Young-Sun,Kim. Kyoung-Woo
- ㆍ 간행물명
- 한국소음진동공학회논문집
- ㆍ 권/호정보
- 2014년|24권 7호|pp.562-568 (7 pages)
- ㆍ 발행정보
- 한국소음진동공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study aimed to identify changes in the physical properties of artificial mineral-fiber materials used as building insulation that had been installed in the outer walls of buildings for a long time. To achieve this goal, glass fiber and rock wool were collected from outer walls in actual buildings and their acoustic and thermal performances were measured. These were compared with measurements from similar products manufactured recently. The results showed that old, used samples had a lower sound absorption coefficient compared to recently manufactured materials. The old samples also displayed increased compressibility compared to new materials. For example, the compressibility difference for glass wool was 7.32 mm. Old samples had a dynamic stiffness $1.28MN/m^3$ higher than new material samples. The thermal conductivity of both old and new samples increased within creasing temperature. They showed similar results at temperatures between 0 and $20^{circ}C$.