기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Efficacy of Cox Maze IV Procedure Using Argon-Based Cryoablation: A Comparative Study with $N_2O$-Based Cryoablation
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Efficacy of Cox Maze IV Procedure Using Argon-Based Cryoablation: A Comparative Study with $N_2O$-Based Cryoablation
  • Efficacy of Cox Maze IV Procedure Using Argon-Based Cryoablation: A Comparative Study with $N_2O$-Based Cryoablation
저자명
Lee. Kyung-Hak,Min. Jooncheol,Kim. Kyung-Hwan,Hwang. Ho Young,Kim. Jun Sung
간행물명
The Korean journal of thoracic and cardiovascular surgery
권/호정보
2014년|47권 4호|pp.367-372 (6 pages)
발행정보
대한흉부외과학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Background: We compared the mid-term results of the Cox maze IV procedure using argon-based cryoablation with a procedure using $N_2O$-based cryoablation. Methods: From May 2006 to June 2012, 138 patients (mean age, $58.2{pm}11.0$ years) underwent the Cox maze IV procedure. Eighty-five patients underwent the maze procedure using an $N_2O$-based cryoprobe (group N), and 53 patients underwent the maze procedure using an argon-based cryoprobe (group A). Bipolar radiofrequency ablation was concomitantly used in 131 patients. The presence of atrial fibrillation immediately, 6 months, 1 year, and 2 years after surgery was compared. Results: Early mortality occurred in 6 patients (4.3%). There were no differences in early mortality or postoperative complications between the two groups. Nineteen of 115 patients (16.5%) remained in atrial fibrillation at postoperative 12 months (14 of 80 patients (17.5%) in group N and 5 of 35 patients (14.3%) in group A, p=0.669). There were no differences in the number of patients who remained in atrial fibrillation at any of the time periods except in the immediate postoperative period. A multivariable analysis revealed that the energy source of cryoablation was not associated with the presence of atrial fibrillation at 1 year (p=0.862) and that a fine F wave (<0.1 mV) was the only risk factor predicting the presence of atrial fibrillation at 1 year (p<0.001, odds ratio=20.287). Conclusion: The Cox maze IV procedure using an argon-based cryoprobe was safe and effective compared with the maze procedure using an $N_2O$-based cryoprobe in terms of operative outcomes and the restoration of sinus rhythm for up to 2 years after surgery.